Micronova Es99 User Manual [verified] • Latest & Newest
The flue gas temperature has exceeded the maximum safety limit set in Pr14 . This is caused by an excessive fuel feed rate, low exhaust fan speed, or heavy ash buildup restricting internal airflow.
$300.00/ea. DISCONTINUED BY MANUFACTURER. CONTROL MODULE. ENERGY SAVING. 12 VAC. 50/60 HZ. 250 MA. FOR ATLAS COPCO AIR COMPRESSOR. Radwell International
When a fault triggers a hard shutdown, correcting the mechanical error will not instantly restore operation. Operators must perform a manual reset on the panel. This is done by holding the for 3–5 seconds until the solid red indicator clears. Troubleshooting Common Fault Codes
To access the technical menu, press , navigate to Technical Settings , and enter the specific security access key (typically code A9 or F8 depending on the specific firmware version utilized by your appliance manufacturer). Core Technical Parameters Reference Table Description Typical Range Factory Default Pr01 Maximum ignition time 15 – 25 mins Pr03 Cleaning cycle interval 20 – 60 mins Pr04 Auger feed time during ignition 0.5 – 3.0 sec Pr06 Auger feed time at Power 1 0.5 – 2.5 sec Pr10 Auger feed time at Power 5 2.5 – 6.0 sec Pr14 Flue gas fan speed at Power 1 800 – 1300 RPM Pr18 Flue gas fan speed at Power 5 1800 – 2400 RPM Troubleshooting & Error Codes micronova es99 user manual
The flue gas extractor fan is blocked, or the encoder sensor cannot read its speed.
⚠️ during autotuning — no manual changes or load variations.
The machine detects incoming electrical line power is improperly ordered, posing a risk of spinning screw elements backward. The flue gas temperature has exceeded the maximum
Power down the machinery completely. Check mechanical components for binding, test input phase balance, and measure winding insulation resistance before resetting the system. Phase Sequence Issues / Incorrect Rotation
Maps input and output matrices over to match alternative legacy environments like the ES3000 platform. Alarms, Fault Flags, and Troubleshooting
The is a vital electronic control module utilized across major industrial rotary screw air compressors . It is widely found in systems from Atlas Copco (such as the GX7–11 series), Ceccato (CSM Maxi series), and ABAC/SPINN. Designed to regulate and monitor key performance parameters like pressure, motor status, and thermal safety, mastering this control unit ensures optimal energy efficiency and prevents costly hardware breakdowns. DISCONTINUED BY MANUFACTURER
Press to enter the user or technical settings menu.
For a complete copy of the manual, you can find various versions hosted on the following platforms: Es99 Controller | PDF - Scribd