Press once to turn on (single beep) or turn off (double beep).

Avoid third-party "manual aggregators" that require payment. Simco generally provides the FMX-002 manual for free.

Before we dissect the manual and the top controls, let’s establish why this device has become a staple in ESD programs. The FMX-002 is a non-contact, high-precision voltmeter capable of measuring both positive and negative electrostatic field voltages from 0 to ±30 kV (at a 1-inch distance).

This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.

This article provides a comprehensive overview of the FMX-002 fieldmeter, its operating procedures, technical specifications, and maintenance guidelines derived from industry standards. Key Technical Specifications Simco FMX-002 Go to product viewer dialog for this item.

Point the sensor at a known grounded or non-charged surface and press the button until the reading shows Targeting:

0 to ±1.49 kV (Low range); ±1.0 kV to ±22.0 kV (High range).

Simco-Ion recommends professional recalibration at least once every 12 months . Calibration must be performed using a precision voltage source and a parallel-plate calibration fixture to verify accuracy across both low and high ranges.

0 to ±1.49 kV (Low range); ±1.0 kV to ±20.0 kV (High range) Measuring Distance: 25 mm ± 0.5 mm (1 inch) Accuracy: ±10%

Related search suggestions:

Proper care ensures long-term accuracy and device longevity. Sensor Care Keep the sensor opening clean and free of dust.

The Simco FMX-002 is a highly reliable, pocket-sized electrostatic fieldmeter used to locate and measure electrostatic charges. Whether you are troubleshooting static on a manufacturing line, auditing an ESD-safe workspace, or verifying the balance of ionizers, this compact device delivers precise, repeatable results.

Connect the plate to a precision high-voltage DC power supply.

Bar graph (red for positive, blue for negative polarity) and digital readout. Operating Instructions 1. Powering On and Zero Calibration

The keyword phrase strongly suggests users are looking at the device’s upper section and struggling to interpret what each component does. Let’s break it down from left to right, top to bottom.

Hold the meter exactly 1 inch away from the grounded surface using the LED range guides.